ODX402/ ODX502/ OODX602 User’s Guide & Operating Manual
3. Operating Instructions
3.1 Human Interface.
3.1.1 Front Panel Channel Select Switches (Circle 3 on figure A)
The ODX602 has a provision of 16 channels. The frequencies
associated with a channel have been factory programmed but can be
changed by the user through the serial RS232 interface. The front
panel has a bank of 8 switches to allow quick switching between
channels. The channels are numbered 0-F (hexadecimal format
wherein A is 10, B is 11 … F is 15) that correspond to the OTX627
channels. A second bank select switch selects Bank 0-7 or 8-F. The
led corresponding to the selected channel glows to indicate the
selected channel.
3.1.2 Front Panel Indicators (Circles 2, 5 & 8 on figure A).
The ODX602 has 4 sets of indicators-
a) Power indicator (Circle 2): This red led indicates the unit is
powered ON. A brief flash when the ‘Power’ is pressed indicates
that the input voltage is too low for operation. This is called a
‘Under-Voltage Lockout’.
b) Channel indicators (Circle 8): These are yellow led’s indicating the
selected channel
c) Bank indicator : This green led when lit indicates that Bank 8-F has
been selected.
d) Link indicators (Circle 5): This is a set of 2 yellow led’s that provide
quick visual indication of the video link. The STATUS led will glow
when the receiver has locked to a valid COFDM signal. The FAIL
led blinks whenever there the link reception has degraded to a
noticeable degree.
3.1.3 OSD Menu Control (Circle 4 on figure A).
This switch allows the user to enable or disable the ‘on-screen
display (OSD)’. It has a 4 settings as explained later.
3.1.4 Power On/Off (Circle 5 on figure A).